REMOTE MONITORING PLATEORM
Monitor system performance in real-time via smartphone app or web portal using our advanced monitoring platform .
- Big lcd display
- Three phase unbalanced output
- Power export limit
- Wifi/GPRS/Lan communication optional
Description

Simpler
Quick and easy single person installation
Fault codes warning view on LCD display
Built-in limiter optional

Safer
Comply with international quality standards tested by TUV, BV,Dekra etc.

Great Reliability
IP65 ingress protection
10+ years R&D accumulation and support

TECHNICAL SPECIFICATION
Model No | DHEPH5KTLXK | DHEPH10KTLXK |
---|---|---|
Input( DC) | ||
Max DC power | 7500W | 15000W |
Max DC voltage | 1000Vd.c. | |
MPPT voltage range | 200...850Vd.c | |
Max input current/per string | 13Ax2 | |
Number of MPP trackers | 2 | |
Number of input string | 2 | |
Battery Input | ||
Battery Type | Li-Lon | |
Battery voltage range | 180-700V | |
Maximum charge/discharge current | 25/25A | |
Charge strategy for Li-tou Battery | Self-adaptation to BMS | |
Output (AC) | ||
AC nominal power | 5000VA | 10000VA |
Max AC apparent power | 5500VA | 11000VA |
Max output current | 10A | 17A |
Nominal AC output | 50/60Hz: 400/350 | |
AC output range | 45/55Hz:280~490Vac(Adj) | |
Power factor | 0.8leading...0.8laging | |
Harmonics factor | <3% | |
Grid type | 3W/N/PE | |
Three-phase unbalance output | 0~100% | |
AC Output (Back-up) | ||
Max AC apparent power | 5000VA | 10000VA |
Norminal Output Voltage | 400/380V | |
Norminal Output Fregency | 50/60HZ | |
Output THDV (@Liuear Load) | <3% | |
Efficiency | ||
Maximum conversion efficiency | 98.00% | 98.20% |
European efficiency | 97.30% | 97.50% |
Max battery to AC Efficiency | 97.20% | 97.40% |
MPPT efficiency | 99.90% | 99.90% |
Safety and Protection | ||
DC reverse-polarity protection | Yes | |
DC breaker | Yes | |
DCIAC SPD | Yes | |
Leakage current protection | Yes | |
Insulation Impedance Detection | Yes | |
Residual Current protection | Yes | |
Output short circuit protection | Yes | |
Battery reerse connection protection | Yes | |
General Parameters | ||
Dimension(W/H/D) | 548*444*184mm | |
Weight | 27 ka | |
Operating temperature range C | -25°C...+60C | |
Degree of protection | IP65 | |
Cooling concept | Natural convection | |
Topology | Transformerless | |
Display | LCD | |
Humidity | 0-95%no condensation | |
Communication | Standard WiFi:GPRS/LAN(optional) | |
Warranty | Standard 5 years; 7/10 years optional | |
BMS communication | CAN/RS485 | |
Meter communication | RS485 | |
Certificates and Approvals | ||
Certificates and Approvals | CQC,VDE-AR-N4105EC61727,IEC62116,VDE0124-AR-N0124,EN50549,IEC62109,IEC62477 |